99久女女精品视频在线观看-99久久综合久中文字幕-99久久综合九九亚洲-99久久综合精品免费-欧美cosplay极品video-欧美brazzers

您好!歡迎訪問上海根生生物科技有限公司網(wǎng)站!
全國服務咨詢熱線:

15216781845

當前位置:首頁 > 產(chǎn)品中心 > > 其它耗材與試劑 > BD556547BD細胞凋亡試劑盒FITC Annexin V Apoptosis Detection Kit I

BD細胞凋亡試劑盒FITC Annexin V Apoptosis Detection Kit I

簡要描述:ContentsAnnexin V-FITC, Propidium Iodide Staining Solution, Annexin V Binding BufferSize100 TestsRegulatory Status RUO
*,*,*,咨詢

  • 產(chǎn)品型號:BD556547
  • 廠商性質(zhì):代理商
  • 更新時間:2025-06-18
  • 訪  問  量:15334

詳細介紹

 Description

Apoptosis is a normal physiologic process which occurs during embryonic development as well as in maintenence of tissue homeostasis. The

apoptotic program is characterized by certain morphologic features, including loss of plasma membrane asymmetry and attachment,

condensation of the cytoplasm and nucleus, and internucleosomal cleavage of DNA. Loss of plasma membrane is one of the earliest features.

In apoptotic cells, the membrane phospholipid phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma

membrane, thereby exposing PS to the external cellular environment. Annexin V is a 35-36 kDa Ca2+ dependent phospholipid-binding

protein that has a high affinity for PS, and binds to cells with exposed PS. Annexin V may be conjugated to fluorochromes including FITC.

This format retains its high affinity for PS and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing

apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, FITC Annexin V staining can identify apoptosis at an earlier

stage than assays based on nuclear changes such as DNA fragmentation.

FITC Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either

apoptotic or necrotic processes. Therefore, staining with FITC Annexin V is typically used in conjunction with a vital dye such as propidium

iodide (PI) or 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells (PI negative, FITC Annexin V

positive). Viable cells with intact membranes exclude PI, wheras the membranes of dead and damaged cells are permeable to PI. For example,

cells that are considered viable are FITC Annexin V and PI negative; cells that are in early apoptosis are FITC Annexin V positive and PI

negative; and cells that are in late apoptosis or already dead are are both FITC Annexin V and PI positive. This assay does not distinguish

between cells that have undergone apoptotic death versus those that have died as a result of a necrotic pathway because in either case, the dead

cells will stain with both FITC Annexin V and PI. However, when apoptosis is measured over time, cells can be often tracked from FITC

Annexin V and PI negative (viable, or no measurable apoptosis), to FITC Annexin V positive and PI negative (early apoptosis, membrane

integrity is present) and finally to FITC Annexin V and PI positive (end stage apoptosis and death). The movement of cells through these three

stages suggests apoptosis. In contrast, a single observation indicating that cells are both FITC Annexin V and PI positive, in of itself, reveals

less information about the process by which the cells underwent their demise.

Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

556547 Rev. 5 Page 1 of 3

Flow Cytometric Analysis of FITC Annexin V staining. Jurkat cells

(Human T-cell leukemia; ATCC TIB-152) were left untreated (top

panels) or treated for 4 hours with 12 μM campotothecin (bottom

panels). Cells were incubated with FITC Annexin V in a buffer

containing propidium iodide (PI) and analyzed by flow cytometry.

Untreated cells were primarily FITC Annexin V and PI negative,

indicating that they were viable and not undergoing apoptosis. After a

4 hour treatment (bottom panels), there were primarily two

populations of cells: Cells that were viable and not undergoing

apoptosis (FITC Annexin V and PI negative) and cells undergoing

apoptosis (FITC Annexin V positive and PI negative). A minor

population of cells were observed to be FITC Annexin V and PI

positive, indicating that they were in end stage apoptosis or already

dead.

Application Notes

Application

Flow cytometry Routinely Tested

Recommended Assay Procedure:

FITC Annexin V is a sensitive probe for identifying apoptotic cells, binding to negatively charged phospholipid surfaces (Kd of ~5 x 10^-2) with

a higher affinity for phosphatidylserine (PS) than most other phospholipids. FITC Annexin V binding is calcium dependent and defined calcium

and salt concentrations are required for optimal staining as described in the FITC Annexin V Staining Protocol. Investigators should note that

FITC Annexin V flow cytometric analysis on adherent cell types (e.g HeLa, NIH 3T3, etc.) is not routinely tested as specific membrane

damage may occur during cell detachment or harvesting. Methods for utilizing Annexin V for flow cytometry on adherent cell types,

however, have been previously reported (Casiola-Rosen et al. and van Engelend et al.).

INDUCTION OF APOPTOSIS BY CAMPTOTHECIN

The following protocol is provided as an illustration on how FITC Annexin V may be used on a cell line (Jurkat).

Materials

1. Prepare Camptothecin stock solution (Sigma-Aldrich Cat. No. C-9911): 1 mM in DMSO.

2. Jurkat T cells (ATCC TIB-152).

Procedure

1. Add Camptothecin (final conc. 4-6 μM) to 1 x 10^6 Jurkat cells.

2. Incubate the cells for 4-6 hr at 37°C.

3. Proceed with the FITC Annexin V Staining Protocol to measure apoptosis.

FITC ANNEXIN V STAINING PROTOCOL

FITC Annexin V is used to quantitatively determine the percentage of cells within a population that are actively undergoing apoptosis. It relies on

the property of cells to lose membrane asymmetry in the early phases of apoptosis. In apoptotic cells, the membrane phospholipid

phosphatidylserine (PS) is translocated from the inner leaflet of the plasma membrane to the outer leaflet, thereby exposing PS to the external

environment. Annexin V is a calcium-dependent phospholipid-binding protein that has a high affinity for PS, and is useful for identifying

apoptotic cells with exposed PS. Propidium Iodide (PI) is a standard flow cytometric viability probe and is used to distinguish viable from

nonviable cells. Viable cells with intact membranes exclude PI, whereas the membranes of dead and damaged cells are permeable to PI. Cells that

stain positive for FITC Annexin V and negative for PI are undergoing apoptosis. Cells that stain positive for both FITC Annexin V and PI are

either in the end stage of apoptosis, are undergoing necrosis, or are already dead. Cells that stain negative for both FITC Annexin V and PI are

alive and not undergoing measurable apoptosis.

556547 Rev. 5 Page 2 of 3

Reagents

1. FITC Annexin V (component no. 51-65874X): Use 5 μl per test.

2. Propidium Iodide (PI) (component no. 51-66211E) is a convenient, ready-to-use nucleic acid dye. Use 5 μl per test.

3. 10X Annexin V Binding Buffer (component no. 51-66121E): 0.1 M Hepes/NaOH (pH 7.4), 1.4 M NaCl, 25 mM CaCl2. For a 1X working

solution, dilute 1 part of the 10X Annexin V Binding Buffer to 9 parts of distilled water.

Staining

1. Wash cells twice with cold PBS and then resuspend cells in 1X Binding Buffer at a concentration of 1 x 10^6 cells/ml.

2. Transfer 100 μl of the solution (1 x 10^5 cells) to a 5 ml culture tube.

3. Add 5 μl of FITC Annexin V and 5 μl PI.

4. Gently vortex the cells and incubate for 15 min at RT (25°C) in the dark.

5. Add 400 μl of 1X Binding Buffer to each tube. Analyze by flow cytometry within 1 hr.

SUGGESTED CONTROLS FOR SETTING UP FLOW CYTOMETRY

The following controls are used to set up compensation and quadrants:

1. Unstained cells.

2. Cells stained with FITC Annexin V (no PI).

3. Cells stained with PI (no FITC Annexin V).

Other Staining Controls:

A cell line that can be easily induced to undergo apoptosis should be used to obtain positive control staining with FITC Annexin V and/or FITC

Annexin V and PI. It is important to note that the basal level of apoptosis and necrosis varies considerably within a population. Thus, even in the

absence of induced apoptosis, most cell populations will contain a minor percentage of cells that are positive for apoptosis (FITC Annexin V

positive, PI negative or FITC Annexin V positive, PI positive).

The untreated population is used to define the basal level of apoptotic and dead cells. The percentage of cells that have been induced to undergo

apoptosis is then determined by subtracting the percentage of apoptotic cells in the untreated population from percentage of apoptotic cells in the

treated population. Since cell death is the eventual outcome of cells undergoing apoptosis, cells in the late stages of apoptosis will have a damaged

membrane and stain positive for PI as well as for FITC Annexin V. Thus the assay does not distinguish between cells that have already undergone

an apoptotic cell death and those that have died as a result of necrotic pathway, because in either case the dead cells will stain with both FITC

Annexin V and PI.

Product Notices

1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.

2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.

Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before

discarding to avoid accumulation of potentially explosive deposits in plumbing.

3.

4. Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.

References

Andree HA, Reuingsperger CP, Hauptmann R, Hemker HC, Hermens WT, Willems GM. Binding of vascular anticoagulant alpha (VAC alpha) to planar

phospholipid bilayers. J Biol Chem. 1990; 265(9):4923-4928. (Biology)

Casciola-Rosen L, Rosen A, Petri M, Schlissel M. Surface blebs on apoptotic cells are sites of enhanced procoagulant activity: implications for coagulation events

and antigenic spread in systemic lupus erythematosus. Proc Natl Acad Sci U S A. 1996; 93(4):1624-1629. (Biology)

Homburg CH, de Haas M, von dem Borne AE, Verhoeven AJ, Reuingsperger CP, Roos D. Human neutrophils lose their surface Fc gamma RIII and acquire

Annexin V binding sites during apoptosis in vitro. Blood. 1995; 85(2):532-540. (Biology)

Koopman G, Reuingsperger CP, Kuijten GA, Keehnen RM, Pals ST, van Oers MH. Annexin V for flow cytometric detection of phosphatidylserine expression on

B cells undergoing apoptosis. Blood. 1994; 84(5):1415-1420. (Biology)

Martin SJ, Reuingsperger CP, McGahon AJ, et al. Early redistribution of plasma membrane phosphatidylserine is a general feature of apoptosis regardless of

the initiating stimulus: inhibition by overexpression of Bcl-2 and Abl. J Exp Med. 1995; 182(5):1545-1556. (Biology)

O'Brien MC, Bolton WE. Comparison of cell viability probes compatible with fixation and permeabilization for combined surface and intracellular staining in flow

cytometry. Cytometry. 1995; 19(3):243-255. (Biology)

Raynal P, Pollard HB. Annexins: the problem of assessing the biological role for a gene family of multifunctional calcium- and phospholipid-binding proteins.

Biochim Biophys Acta. 1994; 1197(1):63-93. (Biology)

Schmid I, Krall WJ, Uittenbogaart CH, Braun J, Giorgi JV. Dead cell discrimination with 7-amino-actinomycin D in combination with dual color immunofluorescence

in single laser flow cytometry. Cytometry. 1992; 13(2):204-208. (Biology)

van Engeland M, Ramaekers FC, Schutte B, Reuingsperger CP. A novel assay to measure loss of plasma membrane asymmetry during apoptosis of adherent

cells in culture. Cytometry. 1996; 24(2):131-139. (Biology)

Vermes I, Haanen C, Steffens-Nakken H, Reuingsperger C. A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early

apoptotic cells using fluorescein labelled Annexin V. J Immunol Methods. 1995; 184(1):39-51. (Biology)

556547

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯數(shù)字),如:三加四=7
上海根生生物科技有限公司
地址:上海市奉賢區(qū)南橋鎮(zhèn)南橋路377號1幢
郵箱:genshengtech@163.com
傳真:86-021-64190979
關注我們
歡迎您關注我們的微信公眾號了解更多信息:
歡迎您關注我們的微信公眾號
了解更多信息
主站蜘蛛池模板: 健力普医疗-半导体激光治疗仪,红外偏振光治疗仪,近红外线治疗仪-独家功能,光疗典范 | 希希助培是专业的教育信息化全场景服务商,为教育培训机构提供教务管理、招生营销、财务管理、家校互动等 | 锯轨机|气动锯轨机|内燃锯轨机|电动钢轨钻孔机|内燃钢轨钻孔机-山东卓力铁路设备有限公司 | 罗湖人才网_罗湖招聘网_求职找工作平台 | 冷却特性测试仪_ 刀柄热胀仪_加油小车价格_皮带张力仪_上海川奇机电设备有限公司 | 苏州温测仪器有限公司-苏州炉温跟踪仪|苏州隔热箱|苏州炉温测试仪|苏州恒温恒湿箱 | 烟台通风管道,烟台风机风管,烟台风阀-烟台福莱通风设备有限公司 烟台天昊矿业有限公司、滑石、滑石粉、微细粉、滑石矿-烟台天昊矿业有限公司 | 青岛熔喷过滤芯_青岛过滤器生产厂家_青岛净水滤料厂家_青岛净达过滤技术有限公司 | 陶瓷靶材_氧化铌靶材_合金靶材_专注河北氧化铌靶材批发-河北东同光电科技有限公司 | 烘焙服定做_定做烘焙制服_工服定制厂家_烘焙服生产厂家-庆洋制衣 | 食品厂净化工程-无尘车间装修改造-净化工程-洁净工程-苏州远盈净化公司 | 申江储气罐厂家,储气罐批发价格,储气罐规格-上海申江压力容器有限公司(厂) | 无锡防火门-防火窗-防火卷帘门-福臣门业科技有限公司 | 亚洲一区日韩一区欧美一区a,中文字幕乱妇无码AV在线,欧美日韩免费在线观看,国产精品一区二区三区免费,日韩精品免费一线在线观看,日韩一本在线,国产呦精品一区二区三区下载,国产日韩精品一区二区在线观看,欧美日韩高清一区二区三区,日韩在线免费观看视频,欧美日韩一区在线观看 | 造型松|泰山迎客松|造型油松-泰安小苹果园林 | 山东金起起重机械有限公司[官网]-金桥银路悬臂吊,金起龙门吊,山东金起起重行吊,单梁起重机 | 上海婺川实业有限公司| 气体检测仪,多功能气体检测仪,四合一检测仪,氯气检测仪,有机挥发气体检测仪,气体报警器-南京诺邦电子科技有限公司 | 物联网环控器-智能养殖监控系统-智能化养殖控制器-养殖环境控制器-朗锐恒科技 | 行李快递安检机-便携式X光安检仪-行李安检机-液体-爆炸物探测仪-安天下安检设备 | 九洲集团官网(300040)—哈尔滨九洲集团股份有限公司 | 什木坊全屋定制官网_木门|护墙|衣柜|橱柜等全品类定制家具 | 烟台蓝天投资开发有限公司 | 开水机-节能开水器-即热式开水器-上海捷水环保科技有限公司 | 上海汽车音响_上海汽车隔音降噪_上海汽车音响改装店_上海音豪 | 重庆电磁流量计_水表厂家_液位计_重庆青天特克科技有限公司 | 微米环境-餐厨/厨余/果蔬垃圾处理设备厂家-大型成套设备解决方案 | 景德镇薪如陶瓷有限公司| 集装箱零配件_不锈钢丝绳厂家_镀锌铁链条_合页非标件定制_上海英鑫多实业有限公司 | 全自动灌装机械设备-迈驰粉末/颗粒/液体/膏体灌装机械设备流水线生产厂家 | 湖北江南专用特种汽车有限公司官方网站 | 磐林投资-大宗林产品现货电子交易|林业碳汇|林权交易|农林产品投资 | 申江储气罐厂家,储气罐批发价格,储气罐规格-上海申江压力容器有限公司(厂) | 智能调光模块,调光系统巨川电气-专注智能照明 | 聚丙烯酰胺,聚合氯化铝,重金属捕捉剂,污泥调理剂,活性氧化铝,生石灰,反渗透阻垢剂,工业葡萄糖,硫酸铝,果壳活性炭,柱状活性炭,蜂窝活性炭,石英砂,锰砂-北京雁归来环保科技有限公司-以真诚为立足之本,以质量为生存之本,愿与海内外同仁共创双赢。雁归来人一路走来,气贯长虹,勇锐盖过怯弱,进取压倒苟安!我们紧扣时代脉搏,专注水处理、继往开来! | 离子交换树脂_阴离子交换树脂_阳离子交换树脂-中国树脂网 | 商业地产策划_商业地产代理_华锦亿爵商业地产顾问机构 | 上海况胜_玻璃反应釜厂家_双层玻璃反应釜_实验室玻璃反应釜 | 上海千舟新材料有限公司-美卓隔膜滤板_奥图泰滤板_压滤机配件 | 印刷公司,北京印刷厂,宣传画册手册印刷厂-和智印彩页设计 | 南宁清洁公司|外墙清洗|开荒清洁|洒水车|管道疏通|园林绿化_广西优而美环境工程有限公司 |